Description
Device for measuring thermal transfers full scale, through a vertical plane wall
The operating principle : The hot and cold enclosures are placed on either side of the wall to test…
Each enclosure is set with a temperature controlled (cold side : between +5°C and –10°C) and hot side (between +10°C and +30°C).
.
he display returns the following data :
temperature gradient between the tested well faces
energy loss through the wall
energy loss caused by thermal bridges
heat flux through the wall
strength and thermal conductivity of the wall
Supplied with :
one set of walls comprising of :
► insulated panel
► insulated dry wall
► double glazed bay
a set of 8 digital temperature probes
an acquisition unit for measuring temperatures and energy consumed
A tactile display for configuration and vizualisation of measurement results
le gradient de température entre les faces de la paroi en test
la perte d’énergie à travers la paroi
la perte d’énergie engendrée par les ponts thermiques
le flux thermique à travers la paroi
la résistance et la conductivité thermique de la paroi
Hot Zone :
Insulated and ventilated
Heating resistances 200W
8 numerical temperature probes
Current and voltage are measured by the central processing unit and are used to calculate the active power of each zone
Cold Zone :
Equipped with a refrigerating unit, an exchanger (cooling) connected to the cold zone and an exchanger (heat) connected to the outside.
Zone is insulated and ventilated.
4 digital temperature probes.